Dynamic Stiffness vs Static Stiffness: Methods and Specs

November 26,2026    bonpora    39

Static load-deflection line and a dynamic stiffness hysteresis loop for the same suspension bushing | BONPORA

Dynamic stiffness is the stiffness a rubber bushing shows under oscillating load at a stated frequency and amplitude. Static stiffness is the slope of its load-deflection curve measured slowly. The first governs noise and impact, the second alignment and deflection, and a drawing that quotes one without the other can be met yet produce the wrong part on the car.

What Dynamic Stiffness and Static Stiffness Describe

A bushing is a controlled compromise. It holds the suspension geometry closely enough that the wheel stays where the alignment specification expects it, allows the articulation and torsion of a moving linkage, and insulates the body from small-amplitude road vibration. Those three jobs pull in different directions, which is why a bonded bush is specified by stiffness rather than by size alone.

The two numbers come from the same part, measured in two different ways.

AttributeStatic stiffnessDynamic stiffness
ExcitationOne slow ramp or a stepped loadSinusoidal load or displacement at a set frequency
What the part feelsElastic response onlyElastic plus viscous response
Typical unitN/mm, or Nm/deg in torsionN/mm, or Nm/deg, at a stated condition
What it is used forDeflection, alignment, clearance, press-fit loadsIsolation, impact feel, structure-borne noise, ride modelling
What it omitsDamping, frequency dependenceNothing about the low-rate behaviour a mechanic feels when prying the arm
Reported asSlope of a load-deflection curveStorage stiffness k', loss stiffness k'', or magnitude abs(k*)

Neither number is the "real" stiffness of the part. Each answers a different question, and the specification has to say which question is being asked. On a suspension bushing, stiffness is normally quoted in three directions separately: radial, axial and torsional, because the elastomer is shaped and voided to behave differently along each axis. A single figure covering all three is not a specification.

Why the Dynamic-to-Static Ratio Changes the Ride Model

For filled rubber compounds in their normal service temperature range, dynamic stiffness is normally higher than static stiffness. The ratio between them, sometimes written Kd/Ks, commonly falls in the region of 1.2 to 1.8 for carbon-black-filled natural rubber at frequencies in the low tens of hertz, with the exact value depending on compound, frequency, amplitude and temperature. That range is typical industry practice rather than a fixed material constant, and it should be confirmed with the supplier on the actual compound.

Three consequences follow.

First, a suspension model built on static rates under-predicts the force transmitted at the frequencies where the body actually complains. Wheel hop and structure-borne road noise sit in the same low-frequency band in which the ratio is largest, so the error is concentrated exactly where it matters.

Second, the ratio is a heat indicator. A compound with strong frequency dependence converts more of each cycle into hysteresis, and hysteresis is heat. On a bush that sees large repeated articulation rather than small vibration, that heat is what ages the compound, hardens it and eventually changes the rate the vehicle was tuned around.

Third, the ratio is a compound signature, not a design constant. Two bushes with identical drawings, identical bore and identical shell can differ in ratio because the compound, the cure state or the void area changed. That is why a stiffness figure without a test condition is not a purchasing document; it is a number that will be met by whichever sample happens to be measured that day.

Test Conditions That Move the Number

The same bushing can be reported at 900 N/mm or at 1,240 N/mm without anyone lying. The difference is in the test conditions, and each of them has to be fixed before a rate can be compared with a competitor's rate or with a previous batch.

ConditionCommon industry settingWhat it does to the reported figureMust appear on the report
Frequency1 to 20 Hz, often 10 or 20 Hz for chassis bushesHigher frequency raises dynamic stiffness in the transition regionYes, as a single value or a short sweep
AmplitudePlus or minus 0.05 to 0.5 mmLarger amplitude usually lowers the reported rateYes, peak or peak-to-peak, stated clearly
PreloadStatic offset representative of ride heightShifts the operating point on a nonlinear curveYes, with the direction of the preload
Temperature23 °C, with a tolerance of about 2 °CColder rubber reads stiffer, warmer reads softerYes, plus conditioning time
Direction and fixtureRadial, axial or torsional, in a rigid fixtureFixture compliance is added to the part's own complianceYes, including a fixture sketch
Waveform and evaluationSine dwell, or a sweep with a stated evaluation pointA sweep peak and a dwell value are not interchangeableYes
ConditioningRest period after moulding, plus a few preconditioning cyclesA freshly moulded bush can read differently from a settled oneYes
Reported quantityk', k'' or abs(k*)At a loss factor of 0.12 the magnitude is under 1% above k'; at 0.30 it is over 4% aboveYes, by name

The last row is the one most often left out. Storage stiffness k' is the in-phase component that stores energy; loss stiffness k'' is the out-of-phase component that dissipates it; the magnitude abs(k*) combines both. For a lightly damped bush the three are close, but for a high-hysteresis compound the gap can exceed a normal acceptance band, and the argument that follows is about vocabulary.

How Dynamic Stiffness and Static Stiffness Are Measured

Static stiffness on a universal test frame

The part is mounted in a fixture that reproduces the installed boundary, meaning the inner tube is loaded through a pin of the correct diameter and the outer shell is supported the way the housing supports it. The crosshead then moves at a controlled rate, commonly between 5 and 25 mm/min for this class of part, and the load-deflection curve is recorded.

Two choices then decide the number. The evaluation range has to be stated, because a bush is rarely linear and the slope near the seating region is not the slope at ride height. And the slope has to be defined as either secant, taken between two points, or tangent, taken at one point. A secant slope over the first millimetre of travel will flatter almost any bush, because that is where clearances are being taken up.

Dynamic stiffness on a servo-hydraulic or electro-dynamic rig

The same fixture is driven sinusoidally while force and displacement are logged together. The ratio of force amplitude to displacement amplitude gives the magnitude, and the phase lag between them gives the loss angle. From those two, storage stiffness and loss stiffness are separated, and the loss factor tan delta follows as k'' divided by k'.

A resonance method, in which a known mass is hung on the bush and the assembly is swept to find its natural frequency, is cheaper. It gives a usable single-frequency result but little control over amplitude and preload, so it is a screening tool rather than a specification tool.

A DMA run on a coupon cut from the compound is a material test, not a part test. It is useful for comparing compounds and for screening formulations, but it cannot tell a buyer what a bonded bush with voids will do in a housing, because it does not include the geometry, the bond or the fixture.

What the report has to state

A stiffness report that can be used in a purchase decision contains the following, in this order.

  1. Part number, drawing revision and batch or sample code.

  2. Test direction, with a sketch of the fixture and the loading axis.

  3. Static rate, evaluation range and crosshead rate.

  4. Dynamic rate at each frequency tested, with amplitude and preload.

  5. Whether the dynamic figure is k', k'' or abs(k*).

  6. Temperature and conditioning time before the test.

  7. Number of samples and the result for each, not only the mean.

  8. Loss factor or phase angle at each condition.

  9. The standard followed, if any, and any deviation from it.

  10. Hardness at the measurement points, since hardness and rate are read together when a batch is questioned.

That list is also the fastest way to grade a report that arrives unsolicited. A single rate with no direction, no amplitude and no temperature is not evidence; it is a sample of one number.

One Bushing, Two Predictions, and the Cost of Finding Out Late

Take an illustrative control arm bush: static radial rate 850 N/mm measured at 10 mm/min over 0 to 2 mm, and dynamic radial rate 1,150 N/mm at 12 Hz with plus or minus 0.1 mm amplitude and a 1.5 kN preload, at a loss factor of 0.12. The ratio is 1.35, comfortably inside the usual band.

Now load it. At a 2.2 kN corner load the bush sits at about 2.6 mm of static deflection. A 5 mm bump input at 12 Hz produces a peak force of about 4,250 N if the model uses the static rate, and about 5,750 N if it uses the dynamic rate. The static model under-predicts the peak by 1,500 N, or roughly 26%, and it does so in the frequency band where the driver hears the result.

The arithmetic repeats with your own numbers: static force is static rate times deflection, dynamic force is dynamic rate times the same deflection, and the gap is the load the static model never saw.

The commercial version of the same error is easier to budget.

Line itemApprove on static data onlyApprove with a dynamic report
Dynamic test, three conditions01,260
Engineering review of the report0390
Replacement prototypes after an NVH complaint2160
Re-test of the revised part1,2600
Air freight for the replacement set4800
Line disruption during changeover1,0200
Engineering review of the complaint1,0400
Total4,0161,650

The figures are an illustrative model built on three test conditions at 420 each, a 65 per hour engineering rate and 12 hours of line disruption. The total matters less than the structure: the test is paid either way, and the version paid after a complaint also carries freight, disruption and a launch delay.

Writing Stiffness Into a Drawing or Purchase Specification

The drawing is where this discussion becomes enforceable. A bush drawing that carries a bore, a shell diameter and a hardness range will produce a dimensional copy of the part. Adding the fields below turns it into a performance document.

FieldWhat to writeWhy it matters
DirectionRadial, axial and torsional, listed separatelyOne number cannot describe a voided bush
Static rateValue, tolerance, evaluation range and loading rateWithout the range, the slope can be taken anywhere
Dynamic rateValue, frequency, amplitude and preloadThe rate is meaningless without its condition
Ratio limitMaximum Kd/Ks, or a minimum and maximum pairCaps hysteresis and keeps the compound honest
TemperatureTest temperature and any cold or hot condition requiredCold-climate and hot-climate markets need separate evidence
Reported quantityk', or abs(k*) if that is what the lab reportsPrevents a 4% disagreement over vocabulary
Sample size and acceptanceFor example three parts, mean within band, no single outlier beyond a wider bandA mean of three hides one bad cavity
HardnessShore A range with tolerance, not a single valueRate and hardness are read together when a batch is questioned
Void layoutPosition, number and approximate area, on the drawingVoids tune one axis and are invisible on a dimensional report
Bond strengthPeel or push-out value and the methodA correct rate on a failing bond is still a failure
Coating and salt sprayFinish and test duration on the tubesCorrosion at the shell changes the press fit
MarkingPart number and batch codeWithout it, a rate complaint cannot be traced to a cavity

Two practical notes on tolerances. A rate band tighter than the process can hold produces a stream of concessions rather than better parts, and a band so wide that it admits both a comfort and a sport compound is not a specification. The band should be set from measured capability on the first three batches, then held.

Where the drawing is silent on stiffness, the supplier will still deliver a bush that presses in and looks right, and the difference will appear in service rather than on the incoming inspection bench. Bonpora supplies bushes moulded and bonded to the bore, shell, length, flange and void layout on the drawing, with hardness, stiffness and bond results available for the batch, and the Bonpora suspension bushing range sets out the construction types and the specification fields in more detail.

Request the stiffness specification sheet or a sample if you are rewriting a drawing that currently specifies only a hardness and a bore. Send it over with the vehicle position and the complaint you are trying to solve, and our engineers will mark which fields are missing and which existing tool is closest.

Where the Specification Meets the Supplier

A rate on a drawing only becomes a part if the supplier can measure it. Four questions separate the suppliers who can from the suppliers who will agree to anything.

The first is whether the rates were measured on a sample or estimated from a similar part. Measured data has a fixture, a condition and a sample count attached. Estimated data has a number and a smile.

The second is which existing tools match the bore, shell and length on your list, because a new tool is a new cure profile and therefore a new set of rates to approve. That conversation belongs before the quotation, not after it.

The third is what the batch documents contain. A certificate of conformance and a dimensional report confirm that the part resembles the drawing; a hardness result, a stiffness result and a bond result confirm that it will behave like the sample that was approved. The bushing manufacturing guide lists the verification steps and the sampling basis behind each of them, including radial and axial stiffness on a universal test frame at first article and then periodically.

The fourth is change control. A change of press, mould or preparation line can alter the cure profile and therefore the rate without any change to the drawing, which is why a requalification sample is a reasonable request before the next shipment on a safety-related position.

Bonding and rate problems rarely announce themselves at goods-in. They surface as a clunk over bumps, vague steering or a bush that has rotated in its housing, and by then the batch is in vehicles. The mounting bushes range covers the constructions, tube materials and elastomer options this article assumes, and the failure analysis page describes the symptoms that a rate error eventually produces.

Frequently Asked Questions

Is dynamic stiffness always higher than static stiffness?

For vulcanised rubber and polyurethane in their normal service range, the dynamic figure is normally higher, because the viscous component adds to the elastic one. The size of the gap depends on compound, frequency, amplitude and temperature, and a very lightly filled compound tested at low frequency can show a gap small enough to be lost in measurement noise.

Can a supplier convert static stiffness into dynamic stiffness with a fixed factor?

Not reliably. The ratio is a property of the compound and the test condition rather than a constant of the part family, so a single factor applied across a range will hide the scatter that matters. Ask for the measured dynamic value at the frequency and amplitude your vehicle model uses.

Which frequency should a drawing specify for a control arm bushing?

Specify the frequency at which the complaint occurs, which for wheel hop and structure-borne road noise is usually in the low tens of hertz. State one dwell frequency and, if the application is sensitive, a short sweep so the trend is visible. A rate quoted at 1 Hz will not describe behaviour at 15 Hz.

Do low-volume aftermarket parts need dynamic data at all?

For a comfort position on a vehicle where noise is part of the complaint, at least one dynamic condition is worth the cost, because it is the only evidence that the compound matches the approved sample. For a non-critical position, a static rate with a stated range, a hardness range and a bond result covers most of the risk.

Why do two laboratories report different rates for the same part?

Fixture compliance, preload, amplitude, evaluation range, temperature and conditioning all move the number, and few labs use identical fixtures. Before treating a difference as a quality problem, compare the two reports field by field; most disagreements resolve into a difference in test condition rather than in the part.

Is torsional stiffness measured the same way?

The principle is the same but the fixture differs: the inner tube is held and the outer shell is rotated, and the result is expressed as Nm per degree rather than N per mm. Torsional rate governs how freely the arm articulates, so it belongs on the drawing next to the radial figure.

back top